Note Details

Category: Processing

November 30, 2006 T.H. See Removed tile C2067 from sample cabinet and mounted in Level 3 fixture after determining proper orientation from the Level 2 mosaic. This tile has a large impact/track on the right end of the tile. Began Level 3 process @ ~08:50. 7x / 20x lighting already in place so these images were acquired first. Completed @ 09:15. Reconfigured system for tungsten light and depth profiles. Completed depth profiles @ 09:45. System configured for detailed track scan and documentation. Tracks: On the first pass, Track B was encountered on the extreme left end and back of the tile from the microscope system. Unfortunately, this position blocks imaging the feature as the left end of the Level 3 fixture impairs the light path to the camera, which is using the left optical path of the stereo microscope. As a result, I plan to flip the tile 180ยบ once I complete documenting the other features in this tile in the normal orientation.