Note Details

Category: Analysis

C118-T3 – Long narrow track with large terminal particle. Angular track measurement is on the order of 1600 to 1620 µm in length. Either the terminal particle or a reflection on the lower track measures nearly 15 µm in size. Some deformity or object in the tile is preventing the camera from getting a good view of the entrance hole. Using the reticule at 80x indicated that the Entrance hole is on the order of 30 µm in size with max track width on the order of 75 FS µm.