Sample C2103,0

Skip to content | Skip to navigation

Site Actions

Site Sections

Breadcrumbs

Home StardustSample CatalogSample C2103,0

Stardust Catalog Sample Information for Sample C2103,0

Information Details

Sample Number: C2103,0 Sample Status: Extracted
Alternate Name: Parent:
Sample Description: Cometary Aerogel Tile
Allocation Status: Available

Subsample List


Sample Description Allocation Status Generic Specific Track Grain Grid
C2103,0,143,0,0  08/18/2008  Available  C2103  0  0  0  0
C2103,0,166,0,0  07/30/2009  Available  C2103  0  0  0  0
C2103,1,98,0,0  Keystone  Available  C2103  0  0  0  0
C2103,1,98,1,0  TERMINAL P ON SLIDE  On Loan  C2103  0  0  0  0
C2103,1,98,2,0  TERMINAL P ON SLIDE  On Loan  C2103  0  0  0  0
C2103,2  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,2,114,0,0  Keystone  On Loan  C2103  0  0  0  0
C2103,3  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,4  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,5  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,6  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,7  BLANK PICO FROM BOTT  Available  C2103  0  0  0  0
C2103,8  BLANK PICO FROM TOP  Available  C2103  0  0  0  0
C2103,9  AEROGEL FRAGMENT with C2103,10,143,9,0  Available  C2103  0  0  0  0
C2103,10,143,0,0  Keystone  Available  C2103  0  0  0  0
C2103,10,143,1,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,10,143,2,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,10,143,3,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,10,143,4,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,10,143,5,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,10,143,6,0  Wall grain on Si  Available  C2103  0  0  0  0
C2103,10,143,7,0  Wall grain on Si  Available  C2103  0  0  0  0
C2103,10,143,8,0  Wall grain on Si  Available  C2103  0  0  0  0
C2103,10,143,9,0  Wall grain on Si  Available  C2103  0  0  0  0
C2103,10,143,10,0  Wall grain on KBR  Available  C2103  0  0  0  0
C2103,11,143,0,0  Dissected Keystone  Unavailable  C2103  0  0  0  0
C2103,12  AEROGEL FRAGMENT with C2103,10,143,1,0  Available  C2103  0  0  0  0
C2103,13  AEROGEL FRAGMENT with C2103,10,143,4,0  Available  C2103  0  0  0  0
C2103,14  AEROGEL FRAGMENT with C2103,10,143,5,0  Available  C2103  0  0  0  0
C2103,15  AEROGEL FRAGMENT with C2103,10,143,6,0  Available  C2103  0  0  0  0
C2103,16  AEROGEL FRAGMENT with C2103,10,143,7,0  Available  C2103  0  0  0  0
C2103,17  AEROGEL FRAGMENT with C2103,10,143,8,0  Available  C2103  0  0  0  0
C2103,18  AEROGEL FRAGMENT  Available  C2103  0  0  0  0
C2103,19  AEROGEL FRAGMENT with C2103,10,143,10,0  Available  C2103  0  0  0  0
C2103,20  BLANK KEYSTONE  Available  C2103  0  0  0  0
C2103,21,166,0,0  07/30/2009  Available  C2103  0  0  0  0
C2103,22,183,0,0  Cometary Keystone With Specimen(s) Dimple Slices  Available  C2103  0  0  0  0
C2103,23,183,0,0  Cometary Dissected Keystone With Specimen(s) Dimple Slices  Available  C2103  0  0  0  0
C2103,24,183,0,0  Cometary Keystone Wafer containing track TP2. ~100um thick  On Loan  C2103  0  0  0  0
C2103,24,183,1,0  Terminal Particle  Unavailable  C2103  0  0  0  0
C2103,24,183,1,1  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,2  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,3  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,4  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,5  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,6  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,7  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,8  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,9  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,10  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,11  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,12  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,13  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,14  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,15  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,16  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,17  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,18  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,19  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,20  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,21  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,22  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,23  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,24  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,25  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,26  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,27  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,28  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,29  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,30  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,31  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,32  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,24,183,1,33  Particle Fragment Ultramicrotomed 150 nm Cu Grid  On Loan  C2103  0  0  0  0
C2103,25,183,0,0  Cometary Dissected Keystone With Specimen(s) Dimple Slices  Available  C2103  0  0  0  0
C2103,26,183,0,0  Cometary Keystone Wafer containing track TP3. ~100um thick  On Loan  C2103  0  0  0  0
C2103,26,183,1,0  Terminal Particle Embedded Potted Butt  On Loan  C2103  0  0  0  0
C2103,26,183,1,1  Particle Fragment Ultramicrotomed SiN TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,2  Particle Fragment Ultramicrotomed Au TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,3  Particle Fragment Ultramicrotomed C TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,4  Particle Fragment Ultramicrotomed C TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,5  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,6  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,7  Particle Fragment Ultramicrotomed C TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,8  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,9  Particle Fragment Ultramicrotomed SiN TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,10  Particle Fragment Ultramicrotomed C TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,11  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,12  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,13  Particle Fragment Ultramicrotomed SiO TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,14  Particle Fragment Ultramicrotomed Au TEM Grid  On Loan  C2103  0  0  0  0
C2103,26,183,1,15  Particle Fragment Ultramicrotomed C TEM Grid  On Loan  C2103  0  0  0  0

Sample Notes

Sample Name Notes Category
C2103,0 C2103-TG – Track G located at13.9 x 12.4 mm. Type A carrot. Length ~702 µm, MBW ~32 µm. TP not obvious but believed to be present. Analysis
C2103,0 Completed track documentation @ 15:00. Took 7x & 20x Top views after changing light source. Completed tile and returned to storage cabinet @ ~15:25. Processing
C2103,0 Cell C2103 was removed from the cometary grid on September 14, 2006. Processing
C2103,0 The tile has several small- to medium-sized tracks. Processing
C2103,0 C2103-TE – Track E located at 13.7 x 1.6 mm. Type B track. Length ~1.23 mm with MBW ~254 µm and EH of 32 µm. TP ~10 µm. Analysis
C2103,0 All track / features (e.g., T1) numbers assigned during the Level 3 scanning are to be considered “Temporary” and in do not relate to the “Official” track number that is assigned when a given features ... Processing
C2103,0 November 28, 2006 T.H. See C2103 10:00 am - Removed Tile C2103 from sample cabinet, determined Level 2 orientation and mounted in Level 3 fixture for scanning. Checked scope alignment. Adjusted alignm ... Processing
C2103,0 C2103-TI – (i no 1) First thought to be Track H, I now believe this is a previously undocumented small track. Locate ~2.2 mm from left end and 9.4 mm (Z = Y) from front surface. Type B track measuring ... Analysis
C2103,0 C2103–TH – Track H for sure. Located @ 6.7 x 9.9 mm. Type A, long carrot. Track Length is 1.2 mm with MBW ~60µm and EH ~18 µm. TP present and less than 10 µm, if not 5. Analysis
C2103,0 C2103-TD – Located @ 17.6 x 10.6 mm. Type A carrot. Length is ~4.43 mm with MBW of 192 µm. Nice TP present. Excellent example of the EH being larger than the throat or track neck that commonly appears ... Analysis
C2103,0 C2103-TB – Located 24.7 x 6.4 mm. Type A carrot. EH appears to be ~70 µm. Dark TP 27 x 22 µm in size. NICE TP. Very black and euhedral in appearance. Little of any aerogel around TP. TP2 is located on ... Analysis
C2103,0 C2103-TA – Located 29.2 x 2.2 mm. Another example of EH being larger than the track’s throat or narrowest area (see C2103-TA_EH image). EH ~213 µm, while throat measures ~160 µm. The track is a Type C ... Analysis
C2103,0 C2103-TC – Located @ 33.7 x 15.3, Type A with two Styli. Overall length ~2.44 mm with Stylus 2 ~1.82 mm. EH is ~31 µm and MBW is ~206 µm. TP1 hard to identify for certain but appears to be ~5 µm. TP 2 ... Analysis
C2103,1,98,0,0 Cell C2103 was removed from the Cometary Tray on September 13, 2006. Level 3 on this track was conducted on November 28, 2006 and Track 98 was assigned temporary track number of TC. Keystone generated ... Processing
C2103,1,98,0,0 Level 3: Temporary track number C2103-TC located @ 33.7 x 15.3, Type A with two Styli. Overall length ~2.44 mm with Stylus 2 ~1.82 mm. EH is ~31 μm and MTW is ~206 μm. TP1 hard to identify for certain ... Processing
C2103,1,98,0,0 Keystone shipped to Tsuchiyama on December 6, 2006. Processing
C2103,1,98,0,0 Cell C2103 was removed from the Cometary Tray on September 13, 2006. Level 3 on this track was conducted on November 28, 2006 and Track 98 was assigned temporary track number of TC. Keystone generated ... Processing
C2103,1,98,0,0 Level 3: Temporary track number C2103-TC located @ 33.7 x 15.3, Type A with two Styli. Overall length ~2.44 mm with Stylus 2 ~1.82 mm. EH is ~31 μm and MTW is ~206 μm. TP1 hard to identify for certain ... Processing
C2103,1,98,0,0 Keystone shipped to Tsuchiyama on December 6, 2006. Processing
C2103,1,98,0,0 Keystone cut by Bastien 12-06, was called track TC
C2103,1,98,0,0 Although temporary track number was called TC, this track most likely corresponds to Track H for the initial track survey done by Penny W. Penny's Track C is still present in C2103 as of 4/5/2011. Inventory
C2103,1,98,0,0 Cell C2103 was removed from the Cometary Tray on September 13, 2006. Level 3 on this track was conducted on November 28, 2006 and Track 98 was assigned temporary track number of TC. Keystone generated ... Processing
C2103,1,98,0,0 Level 3: Temporary track number C2103-TC located @ 33.7 x 15.3, Type A with two Styli. Overall length ~2.44 mm with Stylus 2 ~1.82 mm. EH is ~31 μm and MTW is ~206 μm. TP1 hard to identify for certain ... Processing
C2103,1,98,0,0 Keystone shipped to Tsuchiyama on December 6, 2006. Processing
C2103,2,114,0,0 Keystone cut by Bastien 06/15/2007, was called track G. 820um. 5um terminal particle. Processing
C2103,2,114,0,0 Corrected numbering of keystone from C2103,0,114,0,0 in inventory and C2103,1,114,0,0 in allocation history files. (ntodd) Inventory
C2103,2,114,0,0 Was track G Processing
C2103,2,114,0,0 Was track G Processing
C2103,10,143,0,0 Keystone cut by D. Frank/Particles extracted by K. Nakamura-Messenger
C2103,10,143,0,0 Sample was hand carried from American Museum of Natural History (NYC) to JSC on 5/8/2022 (CO17936)
C2103,11,143,0,0 Dissection by D. Frank
C2103,10,143,9,0 May be lost Inventory
C2103,24,183,1,0 Particle lost 3-11-2014 during ultramicrotomy- particle plucking out of sulfur- B De Gregorio notes received 9-29-2015. Processing
C2103,24,183,1,0 Processing detail of the tp found in De Gregorio LPSC 2015 abstract. Processing
C2103,26,183,1,0 Extracted by B.De Gregorio 8-14-2013 Allocation
C2103,26,183,1,1 Aerogel, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,2 No sample, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,3 Aerogel, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,4 Aerogel, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,5 Aerogel, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,6 80nm, 1 slice, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,7 80nm, 3 slices +2 slices on grid bars, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,8 80nm, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,9 150nm, 2 slices, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,10 90nm, 4 slices, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,11 90nm, 2 slices + 1 possible slice, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,12 90nm, 2 slices +1 slice on grid bar, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,13 90nm, 1 slice +1 slice on grid bar , B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,14 90nm, 2 slices on back side of support film, B.De Gregorio 8-14-2013 microtomy note. Allocation
C2103,26,183,1,15 90nm, 2 slices on grid bars , B.De Gregorio 8-14-2013 microtomy note. Allocation

Sample Photos


C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0

C2103,0
Processing Level 2
C2103,0
Processing Level 2
C2103,0
Processing Level 2
C2103,0
Processing Level 2
C2103,0
Level 3 Photo of Sample C2103,0 - C2103_1
C2103,0
Level 3 Photo of Sample C2103,0 - C2103_2
C2103,0
Level 3 Photo of Sample C2103,0 - C2103_bottom
C2103,0
Level 4
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-a-C+0001-R+0001-L+0000-X+0029684-Y+0001984-Z-0000140
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-a-EH-C+0001-R+0001-L+0000-X+0029731-Y+0001984-Z-0000282
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-a-TP-C+0001-R+0001-L+0000-X+0029684-Y+0001984-Z-0000736
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-C+0001-R+0001-L+0000-X+0245723-Y+006074-Z+0000288
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-C+0001-R+0001-L+0000-X+0246258-Y+006006-Z-0003876
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-Bottom-C+0001-R+0001-L+0000-X+0245495-Y+0006074-Z-0003510
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-Top-C+0001-R+0001-L+0000-X+0245495-Y+0006074-Z-0001367
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-TP-C+0001-R+0001-L+0000-X+0245495-Y+006006-Z-0006104
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-TP2-C+0001-R+0001-L+0000-X+0246258-Y+006006-Z-0002379
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-TP3-C+0001-R+0001-L+0000-X+0246258-Y+006006-Z-0003324
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-b-TP4-C+0001-R+0001-L+0000-X+0245724-Y+006006-Z-0005257
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-c_bottom_C+0001_R+0001_L+0000_X+036566_Y+0166343_Z-0002041
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-c-C+0001-R+0001-L+0000-X+036566-Y+0166343-Z-0001250
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-c_top_C+0001_R+0001_L+0000_X+036566_Y+0166343_Z-0000979
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-c-EH-C+0001-R+0001-L+0000-X+036566-Y+0166343-Z-0000034
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-c-TP-C+0001-R+0001-L+0000-X+036566-Y+0166343-Z-0002969
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-d-C+0001-R+0001-L+0000-X+017701-Y+010445-Z-0002714
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-d-EH-C+0001-R+0001-L+0000-X+017701-Y+010445-Z-0000442
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-d-EH-C+0001-R+0001-L+0000-X+0245495-Y+0006074-Z-0000784
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-d-TP-C+0001-R+0001-L+0000-X+0016462-Y+0010413-Z-0004728
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-d-TP-C+0001-R+0001-L+0000-X+017701-Y+010445-Z-0004095
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-e-C+0001-R+0001-L+0000-X+0236384-Y+0150609-Z-0000891
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-e-EH-C+0001-R+0001-L+0000-X+0236384-Y+0150609-Z+0000092
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-e-TP-C+0001-R+0001-L+0000-X+0236384-Y+0150609-Z-0001764
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-g-C+0001-R+0001-L+0000-X+0013855-Y+0011406-Z+0000478
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-g-EH-C+0001-R+0001-L+0000-X+0013663-Y+0011406-Z+0000750
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-g-TP-C+0001-R+0001-L+0000-X+0013663-Y+0011406-Z+0000000
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-h-C+0001-R+0001-L+0000-X+0006695-Y+0009490-Z+0001139
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-h-EH-C+0001-R+0001-L+0000-X+0006539-Y+0009136-Z+0001942
C2103,0
Level 3 Photo of Sample C2103,0 - C2103-h-TP-C+0001-R+0001-L+0000-X+0006195-Y+0009136-Z-0000524
C2103,0
Processing Level 1
C2103,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0
Level 4
C2103,0,143,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,0,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,1,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0

C2103,1,98,2,0
Image taken after PI return sample
C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,10,143,0,0

C2103,11,143,0,0

C2103,11,143,0,0

C2103,11,143,0,0

C2103,11,143,0,0

C2103,11,143,0,0

C2103,11,143,0,0
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Level 4
C2103,2,114,0,0
Image taken after PI return sample
C2103,21,166,0,0

C2103,22,183,0,0

C2103,22,183,0,0

C2103,24,183,0,0

C2103,24,183,0,0

C2103,24,183,0,0

C2103,24,183,0,0

C2103,24,183,0,0

C2103,26,183,0,0

C2103,26,183,0,0

C2103,26,183,0,0
Level 4
C2103,3
Level 4
C2103,3
Level 4
C2103,3
Level 4
C2103,3
Level 4
C2103,3
Level 4
C2103,3
Level 4
C2103,4
Level 4
C2103,4
Level 4
C2103,4
Level 4
C2103,4
Level 4
C2103,4
Level 4
C2103,5
Level 4
C2103,5
Level 4
C2103,5
Level 4
C2103,6
Level 4
C2103,7
Level 4
C2103,7
Level 4
C2103,7
Level 4
C2103,8
Level 4
C2103,8
Level 4
C2103,8

Related Documents

File Name Sample Name Description Size File Type
15º Offset Scanning Log C2103,0 467968 KB doc
Khodja_2009_lpsc_1746 C2103,1,98,1,0 193173 KB pdf
Khodja_2009_lpsc_1746 C2103,1,98,2,0 193173 KB pdf
15ºOffset_Penny-Tom C2103,0 376320 KB xls
degregorio2759 C2103,24,183,0,0 243028 KB pdf
degregorioLPSC20152625 C2103,24,183,1,0 426094 KB pdf
15ºOffset C2103,0 376320 KB xls
STARDUST SAMPLE RETURN FORM rotundi C2103,10,143,0,0 60928 KB dot
Track 98 CO14863 Herzog-C2103-1-98-1~2-0-low C2103,1,98,1,0 260096 KB ppt
Track 98 CO14863 Herzog-C2103-1-98-1~2-0-low C2103,1,98,2,0 260096 KB ppt
Track_114 C2103,2,114,0,0 Level 4 9013248 KB xls
SampleLossConsumptionForm rotundi C2103,10,143,9,0 25600 KB dot
Track 10 or 143 Report_LANDS_2 rotundi C2103,0,143,0,0 607232 KB doc
Tracks - Impact Angle C2103,0 73728 KB xls
Tracks 96 _ 97_ 98 summary C2103,1,98,0,0 252171 KB pdf
white2292-sdl C2103,10,143,0,0 1175306 KB pdf
Tracks 96 _ 97_ 98 summary1 C2103,1,98,0,0 252171 KB pdf
Track 143 C2103,10,143,0,0 242176 KB ppt
Track 143 CO15092_Rotundi_C2103_T143_grains_LOW C2103,10,143,0,0 1337856 KB ppt
C103 C2103,0 1544704 KB ppt